Porte con ante in vetro
Perfect for a panoramic lift installation
Porte con ante in vetro
Glass panels doors give any installation a distinctive style; they are perfect for a panoramic lift installation, but can also offer more openness and light to a closed shaft lift.
The current standard allow you the utilisation of new solutions representing the maximum as far as safety, design and elegance concerns matching innovation and cost saving.
The doors are supplied in any kind of configuration and are available in two, three, four and six panels.
Porte con ante vetrate
To restore with class any installation
Porte con ante vetrate
Glass-framed panels doors may restore with class any installation, from the panoramic one to the installations with closed shaft.
DiscoverPorte resistenti al fuoco con ante vetrate
Norme EN 81-58 - Classe "E" e altre normative
Porte resistenti al fuoco con ante vetrate
DiscoverPorte resistenti al fuoco Classe "E"
Norme EN 81-58
Porte resistenti al fuoco Classe "E"
The fire resistant lift landing doors are the most diffused in Europe and in the world.
DiscoverPorte resistenti al fuoco Classe "EW"
Norme EN 81-58
Porte resistenti al fuoco Classe "EW"
The fire resistant lift landing doors are the most diffused in Europe and in the world. Their essential feature is to satisfy the fire resistance requirements of the fireproof rules for the buildings.
DiscoverPorte resistenti al fuoco Classe "EI"
Norme EN 81-58
Porte resistenti al fuoco Classe "EI"
The fire resistant lift landing doors are the most diffused in Europe and in the world. Their essential feature is to satisfy the fire resistance requirements of the fireproof rules for the buildings.
DiscoverPorte a norme DIN 18091
Mainly produced for the German market
Porte a norme DIN 18091
The fire resistant landing doors according to DIN 18091 standard are mainly produced for the German market and for all the countries where these standards are accepted.
DiscoverStipiti speciali
Stipiti angolari o tubolari
Stipiti speciali
These particular types of frames are designed to simplify the modernization of existing lifts.
DiscoverImpianti antideflagranti
Impianti antideflagranti
A mechanism or operator in explosionproof execution is able to avoid the triggering of sparks, according to 1127:1997 standards
DiscoverImpianti IP54
Impianti IP54
DiscoverCertificazione antivandalo per porte
Secondo lo standard EN 81-71:2018
Certificazione antivandalo per porte
DiscoverPorte per applicazioni Marine
Porte per applicazioni Marine
These doors combine technological research with aesthetics with an high level of customization.
DiscoverPorte standard
Porte standard
Wittur realizes a wide range of doors in standard execution supplying ideal solutions for each and every market requirement.
DiscoverPorte per ascensore antincendio secondo EN 81-72:2015
Porte per ascensore antincendio secondo EN 81-72:2015
A Firefighter Elevator is a system that, in standard conditions, is used by passengers, while, in event of fire, it is used by Firefighters who can change its operating mode thanks to special controllers
DiscoverPorte ascensore certificate antivandalo EN 81-71 categoria 2
Porte ascensore certificate antivandalo EN 81-71 categoria 2
Wittur Pegasus range of landing and car door types are available with full compliance to the vandal-resistant certification category 2 according to EN 81-71 European standard.
DiscoverProduct Comparison Tool
| Augusta Evo |
C-MOD |
Hydra |
B-HR |
B-G |
Fineline® |
ECO BUS |
MOD KITS |
Luna |
Nettuno |
Taurus |
SWS |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Up to 2 m/s |
Up to 2 m/s |
Up to 4 m/s |
Starting from 5 m/s |
Up to 3 m/s |
Up to 2 m/s |
Up to 4 m/s |
Up to 3 m/s |
Up to 3 m/s |
Up to 3 m/s |
Up to 3,5 m/s |
Up to 2 m/s |
Clear opening (mm) |
700 - 1100 |
600 - 1400 |
700 - 1600 |
700 - 2400 |
700 - 3500 |
600 - 900 |
600 - 3500 |
600 - 1800 |
600 - 3200 |
800 - 5000 |
800 - 1200 |
500 - 1100 |
Clear height (mm) * |
2000 - 2200 |
2000 - 2300 |
2000 - 2600 |
2000 - 3000 |
2000 - 3500 |
1900 - 2100 |
1900 - 3500 |
2000 - 3500 |
1900 - 3500 |
2000 - 5000 |
2000 - 2200 |
2000 - 2100 |
C2 / Sill package (mm) |
130 |
117 |
180 |
200 |
165 |
85 |
Underdriven 186 / Top driven 180 |
180 |
75 |
240 |
— |
|
T2 / Sill package (mm) |
180 |
185 |
210 |
270 |
255 |
115 |
|
— |
270 |
123 |
290 |
— |
T3 / Sill package (mm) |
— |
273 |
256 / 302 |
— |
345 |
— |
|
— |
— |
182 |
— |
— |
C4 / Sill package (mm) |
— |
185 |
210 |
270 |
255 |
Asymmetrical 115 |
|
— |
270 |
123 |
— |
130 |
C6 / Sill package (mm) |
— |
— |
302 |
— |
345 |
— |
— |
— |
— |
182 |
— |
— |
T1 / Sill package (mm) |
— |
— |
180 |
— |
— |
— |
— |
Underdriven 186 / Top driven 180 |
180 |
— |
— |
— |
Full glass |
— |
|
|
|
— |
|
|
|
— |
— |
||
Framed Glass |
— |
|
|
|
— |
|
|
|
|
— |
||
EN 81-20/50 |
|
|
|
|
|
|
|
|
|
|
||
EN 81-71 |
— |
Cat. 1 |
Cat. 1 |
Cat 1 |
Cat 1, Cat 2 |
— |
— |
Cat.1 |
— |
— |
Cat 1, Cat 2 |
— |
EN 81-72 |
— |
|
|
|
— |
— |
— |
|
|
|
— |
|
EN 81-58 E |
|
|
|
|
|
|
|
|
|
— |
||
EN 81-58 EI |
|
|
|
— |
|
— |
— |
|
|
— |
||
BS 476 E |
|
|
|
— |
|
|
|
|
— |
— |
||
GOST |
— |
|
|
|
— |
|
— |
— |
— |
— |
— |
|
Aluminium sill |
|
|
|
|
|
— |
— |
— |
|
|
||
Reinforced sill |
— |
|
|
|
— |
|
|
|
|
|
— |
|
Hidden sill |
— |
— |
|
|
— |
|
|
|
— |
|
— |
|
Door closing |
Spring |
Spirator |
Counterweight |
Counterweight |
Counterweight |
Counterweight |
Various |
Spring |
Spirator |
Counterweight |
Spirator |
Spring |
Light curtain |
Fixed |
Fixed |
Fixed and dynamic |
Fixed and dynamic |
Fixed and dynamic |
Fixed |
Fixed and dynamic |
Fixed and dynamic |
Fixed and dynamic |
Fixed and dynamic |
Dynamic |
Fixed |
IP54 |
— |
|
|
|
— |
|
|
|
|
|
— |
|
Door Drive |
ECO+ |
SZS / SDS |
ECO+ |
SDS |
SDS SDS MV |
ECO+ |
Various |
SUPRA |
MIDI+ SUPRA |
Industrial motor |
SDS, SWS + IRDA |
ECO+ |