Features

SGV door system in a variety of applications, from SGV6 medium duty doors for elevators in residential buildings up to SGV2 doors for high duty elevators in office buildings and hotels.
It's available as a complete entrance with a range of options for frame (16ga, 14ga), sill assembly, and panels (single skin, double skin, cladded, framed glass) in several distinctive finishes.
SGV is also available as a modernization kit for most OEM's.
MOD kits iclude:
- adjustable car door operator brackets;
- door panel adapters to interface with existing door panels;
- clutch with integrated car door interlock.

- Easy access and control of operator from the entrance or from the cab roof.
- Low space requirement leaves rooftop free of equipment
- Simple maintenance with few moving parts
- Dependable electronics with a multitude of options
- Heavy duty clutch CSA certified car door interlock eliminates the need for additional restrictors
- Large PU Coated Ø 3 3/4” (94mm) hanger Rollers for reliable and silent operation

- SGV is compliant with ASME A17.1/B44 and certified by CSA NRTL/C, including certified car door interlock.
- SGV doors are also available in fire resistant execution certified according to UL 10B 1-1/2H, door heights up to 120”.
Product Overview
MIDI+ | SUPRA | |
Motor characteristics | 3 phase permanent Magnet Synchron Motor |
3 phase permanent Magnet Synchron Motor |
Drive | V3F-Converter (Vector Control) |
V3F-Converter (Vector Control) |
Average Power Consumption |
92W | 170W |
Max Momentary Power Consumption |
475W | 900W |
Power Supply | Univ. 115-230 V +/-20% 50/60 Hz |
Univ. 115-230 V +/-20% 50/60 Hz |
Max Speed | 2 ft/s (0.6 m/s) | 3.3 ft/s (1.0 m/s) |
Max Panel Weight by Railing |
SGV6 = 140 Ib (65kg) | SGV2 = 275 Ib (125kg) |
Protection Class | IP20 | IP20 |
Storage Temperature | -45 .... +70°C | -45 .... +70°C |
Operating Ambient Temperature |
-20 .... +50°C | -20 .... +50°C |
Humidity Range | 98% max 40°C | 98% max 40°C |
Regulations and Codes |
EN 81, ASME A17.5, CAN/CSA-B441 | |
Electromagnetic Compatibility |
Immunity and emission protection acc. EN 12015/16 |
|
Max. Movable Masses (car and landing door panels) |
595 Ibs / 270 kg | 1320 Ibs / 600 kg |
Noise Level (door operator) |
Average 55 dB, max 60 dB |
Average 50 dB, max 55 dB |
Estimated Lifetime | More than 3 milion cycles |
More than 5 milion cycles |